Subversion Repositories configs

Rev

Details | Last modification | View Log | RSS feed

Rev Author Line No. Line
4 - 1
# Plustek-SANE Backend configuration file
2
# For use with LM9831/2/3 based USB scanners
3
#
4
 
5
# each device needs at least two lines:
6
# - [usb] vendor-ID and product-ID
7
# - device devicename
8
# i.e. for Plustek (0x07B3) UT12/16/24 (0x0017)
9
# [usb] 0x07B3 0x0017
10
# device /dev/usbscanner
11
# or
12
# device libusb:bbb:ddd
13
# where bbb is the busnumber and ddd the device number
14
# make sure that your user has access to /proc/bus/usb/bbb/ddd
15
#
16
# additionally you can specify some options
17
# warmup, lOffOnEnd, lampOff
18
#
19
# For autodetection use
20
# [usb]
21
# device /dev/usbscanner
22
#
23
# or simply
24
# [usb]
25
#
26
# or if you want a specific device but you have no idea about the
27
# device node or you use libusb, simply set vendor- and product-ID
28
# [usb] 0x07B3 0x0017
29
# device auto
30
#
31
# NOTE: autodetection is safe, as it uses the info it got
32
#       from the USB subsystem. If you're not using the
33
#       autodetection, you MUST have attached that device
34
#       at your USB-port, that you have specified...
35
#
36
 
37
[usb]
38
 
39
#
40
# options for the previous USB entry
41
#
42
# switch lamp off after xxx secs, 0 disables the feature
43
# (can also be set via frontend)
44
option lampOff 300
45
 
46
# warmup period in seconds, 0 means no warmup, -1 means auto-warmup
47
# (can also be set via frontend)
48
option warmup -1
49
 
50
# 0 means leave lamp-status untouched, not 0 means switch off
51
# on sane_close
52
# (can also be set via frontend)
53
option lOffOnEnd 1
54
 
55
#
56
# options to tweak the image start-position
57
# (WARNING: there's no internal range check!!!)
58
#
59
# for the normal scan area
60
#
61
option posOffX 0
62
option posOffY 0
63
 
64
# for transparencies
65
option tpaOffX 0
66
option tpaOffY 0
67
 
68
# for negatives
69
option negOffX 0
70
option negOffY 0
71
 
72
#
73
# for setting the calibration strip position
74
# (WARNING: there's no internal range check!!!)
75
# -1 means use built in
76
# (can also be set via frontend)
77
option posShadingY -1
78
option tpaShadingY -1
79
option negShadingY -1
80
 
81
#
82
# to invert the negatives, 0 disables the feature
83
#
84
option invertNegatives 0
85
 
86
#
87
# to disable the internal sensor speedup function,
88
# 1 disables the feature
89
#
90
option disableSpeedup 0
91
 
92
#
93
# to save/restore coarse calibration data
94
# (can also be set via frontend)
95
option cacheCalData 0
96
 
97
#
98
# use alternate calibration routines
99
#
100
option altCalibration 0
101
 
102
#
103
# for skipping whole calibration step
104
#
105
option skipCalibration 0
106
 
107
#
108
# for skipping entire fine calibration step
109
# coarse calibration is done
110
#
111
option skipFine 0
112
 
113
#
114
# discard the result of the fine white calibration
115
#
116
option skipFineWhite 0
117
 
118
#
119
# some scanners have a dark calibration strip, in
120
# general this one should be used for calibration.
121
# As this could cause some trouble, this option
122
# overrides that and the dark calibration will be
123
# done by switching the lamp off
124
#
125
option skipDarkStrip 0
126
 
127
# for replacing the gain values found during coarse
128
# calibration
129
# (can also be set via frontend)
130
option red_gain   -1
131
option green_gain -1
132
option blue_gain  -1
133
 
134
# for replacing the offset values found during coarse
135
# calibration
136
# (can also be set via frontend)
137
option red_offset   -1
138
option green_offset -1
139
option blue_offset  -1
140
 
141
#
142
# for replacing the default lampoff settings, this
143
# works only for CIS devices like CanoScan LiDE20
144
# (can also be set via frontend)
145
option red_lampoff   -1
146
option green_lampoff -1
147
option blue_lampoff  -1
148
 
149
#
150
# for adjusting the default gamma values
151
# (can also be set via frontend)
152
option redGamma         1.0
153
option greenGamma       1.0
154
option blueGamma        1.0
155
option grayGamma        1.0
156
 
157
#
158
# to enable TPA (EPSON or UMAX, if autodetection fails)
159
# 0 means default behaviour as specified in the internal tables
160
# 1 means enable (needed for UMAX 3450)
161
option enableTPA 0
162
 
163
#
164
# model override functionality, currently only available for
165
# Mustek devices, using NSCs' vendor ID: 0x0400 and
166
# also their product ID: 0x1000 (LM9831) 0x1001 (LM9832)
167
#
168
# mov/PID    |    0x1000   |   0x1001
169
# ---------------------------------------
170
# 0 (default)| BearPaw1200 | BearPaw 2400
171
# 1          |   ignored   | BearPaw 1200
172
#
173
option mov 0
174
 
175
#
176
# and of course the device-name
177
#
178
# device /dev/usbscanner
179
device auto
180
 
181
#
182
# to define a new device, start with a new section:
183
# [usb]
184
#