4 |
- |
1 |
# the ST400 is fixed to ID 3
|
|
|
2 |
scsi SIEMENS "ST 400" Scanner * * 3 *
|
|
|
3 |
scsi SIEMENS "ST 800" Scanner * * 3 *
|
|
|
4 |
|
|
|
5 |
# The following options are for testing and bug-hunting. If your scanner
|
|
|
6 |
# needs one of these options to function reliably, please let me know.
|
|
|
7 |
|
|
|
8 |
# Maximum amount of data to read in a single SCSI command. If not set
|
|
|
9 |
# (or set to 0), the backend will read as much data as allowed by the
|
|
|
10 |
# scanner model or the OS. WARNING: Using this option overrides the
|
|
|
11 |
# hardcoded # maxread limits for all scanner models! With more than
|
|
|
12 |
# 65536 bytes, my ST400 locks up (itself, the SCSI bus, the sg driver,
|
|
|
13 |
# and the machine). Use with caution.
|
|
|
14 |
#option maxread 65536
|
|
|
15 |
|
|
|
16 |
# Use this to switch the scanner lights on with a separate MODE SELECT call
|
|
|
17 |
# and wait for some time before starting to scan (to allow the lights to go
|
|
|
18 |
# to full intensity). The time is in 1/10 seconds (i.e. 20 means 2 seconds).
|
|
|
19 |
# If not set, scanning starts immediately (works with my ST400).
|
|
|
20 |
#option delay 20
|
|
|
21 |
|
|
|
22 |
# The following are hacks that affect all scanners of the same model as the
|
|
|
23 |
# last attached device. Used like this (assume ST800's had 8bit depth and
|
|
|
24 |
# 4MB internal buffer):
|
|
|
25 |
# scsi SIEMENS "ST 400" Scanner * * 3 *
|
|
|
26 |
# option scanner_bufsize 2097152
|
|
|
27 |
# option scanner_bits 6
|
|
|
28 |
# scsi SIEMENS "ST 800" Scanner * * 3 *
|
|
|
29 |
# option scanner_bufsize 4194304
|
|
|
30 |
# option scanner_bits 8
|
|
|
31 |
# Currently, the backend has entries for ST400, ST800 and "everything else".
|
|
|
32 |
# To add more scanners, you have to add a line in the st400_models array.
|
|
|
33 |
# Please note that these options are only for testing unknown devices with
|
|
|
34 |
# this backend.
|
|
|
35 |
|
|
|
36 |
# Internal scanner buffer:
|
|
|
37 |
#option scanner_bufsize 2097152
|
|
|
38 |
|
|
|
39 |
# Bit depth:
|
|
|
40 |
#option scanner_bits 6
|
|
|
41 |
|
|
|
42 |
# Maximum bytes to read in a single SCSI command (see also maxread above).
|
|
|
43 |
#option scanner_maxread 65536
|
|
|
44 |
|
|
|
45 |
# Supported resolutions (upto 15 different values). If you specify an
|
|
|
46 |
# illegal value here, most likely the scanner will not report an error,
|
|
|
47 |
# but only scan a small sub-area of the requested area (at least my ST400
|
|
|
48 |
# does this).
|
|
|
49 |
#option scanner_resolutions 200 300 400
|
|
|
50 |
|
|
|
51 |
# This option causes the SCSI inquiry response to be written to
|
|
|
52 |
# "$HOME/st400.dump" (as binary data). For debugging purposes.
|
|
|
53 |
#option dump_inquiry
|