Subversion Repositories configs

Rev

Details | Last modification | View Log | RSS feed

Rev Author Line No. Line
4 - 1
# the ST400 is fixed to ID 3
2
scsi SIEMENS "ST 400" Scanner * * 3 *
3
scsi SIEMENS "ST 800" Scanner * * 3 *
4
 
5
# The following options are for testing and bug-hunting.  If your scanner
6
# needs one of these options to function reliably, please let me know.
7
 
8
# Maximum amount of data to read in a single SCSI command.  If not set
9
# (or set to 0), the backend will read as much data as allowed by the
10
# scanner model or the OS.  WARNING: Using this option overrides the
11
# hardcoded # maxread limits for all scanner models!  With more than
12
# 65536 bytes, my ST400 locks up (itself, the SCSI bus, the sg driver,
13
# and the machine). Use with caution.
14
#option maxread 65536
15
 
16
# Use this to switch the scanner lights on with a separate MODE SELECT call
17
# and wait for some time before starting to scan (to allow the lights to go
18
# to full intensity).  The time is in 1/10 seconds (i.e. 20 means 2 seconds).
19
# If not set, scanning starts immediately (works with my ST400).
20
#option delay 20
21
 
22
# The following are hacks that affect all scanners of the same model as the
23
# last attached device.  Used like this (assume ST800's had 8bit depth and
24
# 4MB internal buffer):
25
#   scsi SIEMENS "ST 400" Scanner * * 3 *
26
#   option scanner_bufsize 2097152
27
#   option scanner_bits 6
28
#   scsi SIEMENS "ST 800" Scanner * * 3 *
29
#   option scanner_bufsize 4194304
30
#   option scanner_bits 8
31
# Currently, the backend has entries for ST400, ST800 and "everything else".
32
# To add more scanners, you have to add a line in the st400_models array.
33
# Please note that these options are only for testing unknown devices with
34
# this backend.
35
 
36
# Internal scanner buffer:
37
#option scanner_bufsize 2097152
38
 
39
# Bit depth:
40
#option scanner_bits 6
41
 
42
# Maximum bytes to read in a single SCSI command (see also maxread above).
43
#option scanner_maxread 65536
44
 
45
# Supported resolutions (upto 15 different values).  If you specify an
46
# illegal value here, most likely the scanner will not report an error,
47
# but only scan a small sub-area of the requested area (at least my ST400
48
# does this).
49
#option scanner_resolutions 200 300 400
50
 
51
# This option causes the SCSI inquiry response to be written to
52
# "$HOME/st400.dump" (as binary data).  For debugging purposes.
53
#option dump_inquiry