Blame | Last modification | View Log | RSS feed
# Plustek-SANE Backend configuration file# For use with LM9831/2/3 based USB scanners## each device needs at least two lines:# - [usb] vendor-ID and product-ID# - device devicename# i.e. for Plustek (0x07B3) UT12/16/24 (0x0017)# [usb] 0x07B3 0x0017# device /dev/usbscanner# or# device libusb:bbb:ddd# where bbb is the busnumber and ddd the device number# make sure that your user has access to /proc/bus/usb/bbb/ddd## additionally you can specify some options# warmup, lOffOnEnd, lampOff## For autodetection use# [usb]# device /dev/usbscanner## or simply# [usb]## or if you want a specific device but you have no idea about the# device node or you use libusb, simply set vendor- and product-ID# [usb] 0x07B3 0x0017# device auto## NOTE: autodetection is safe, as it uses the info it got# from the USB subsystem. If you're not using the# autodetection, you MUST have attached that device# at your USB-port, that you have specified...#[usb]## options for the previous USB entry## switch lamp off after xxx secs, 0 disables the feature# (can also be set via frontend)option lampOff 300# warmup period in seconds, 0 means no warmup, -1 means auto-warmup# (can also be set via frontend)option warmup -1# 0 means leave lamp-status untouched, not 0 means switch off# on sane_close# (can also be set via frontend)option lOffOnEnd 1## options to tweak the image start-position# (WARNING: there's no internal range check!!!)## for the normal scan area#option posOffX 0option posOffY 0# for transparenciesoption tpaOffX 0option tpaOffY 0# for negativesoption negOffX 0option negOffY 0## for setting the calibration strip position# (WARNING: there's no internal range check!!!)# -1 means use built in# (can also be set via frontend)option posShadingY -1option tpaShadingY -1option negShadingY -1## to invert the negatives, 0 disables the feature#option invertNegatives 0## to disable the internal sensor speedup function,# 1 disables the feature#option disableSpeedup 0## to save/restore coarse calibration data# (can also be set via frontend)option cacheCalData 0## use alternate calibration routines#option altCalibration 0## for skipping whole calibration step#option skipCalibration 0## for skipping entire fine calibration step# coarse calibration is done#option skipFine 0## discard the result of the fine white calibration#option skipFineWhite 0## some scanners have a dark calibration strip, in# general this one should be used for calibration.# As this could cause some trouble, this option# overrides that and the dark calibration will be# done by switching the lamp off#option skipDarkStrip 0# for replacing the gain values found during coarse# calibration# (can also be set via frontend)option red_gain -1option green_gain -1option blue_gain -1# for replacing the offset values found during coarse# calibration# (can also be set via frontend)option red_offset -1option green_offset -1option blue_offset -1## for replacing the default lampoff settings, this# works only for CIS devices like CanoScan LiDE20# (can also be set via frontend)option red_lampoff -1option green_lampoff -1option blue_lampoff -1## for adjusting the default gamma values# (can also be set via frontend)option redGamma 1.0option greenGamma 1.0option blueGamma 1.0option grayGamma 1.0## to enable TPA (EPSON or UMAX, if autodetection fails)# 0 means default behaviour as specified in the internal tables# 1 means enable (needed for UMAX 3450)option enableTPA 0## model override functionality, currently only available for# Mustek devices, using NSCs' vendor ID: 0x0400 and# also their product ID: 0x1000 (LM9831) 0x1001 (LM9832)## mov/PID | 0x1000 | 0x1001# ---------------------------------------# 0 (default)| BearPaw1200 | BearPaw 2400# 1 | ignored | BearPaw 1200#option mov 0## and of course the device-name## device /dev/usbscannerdevice auto## to define a new device, start with a new section:# [usb]#